- Designed to connect third–party hardware such as alarm controllers
and home automation systems to X10
- Compatible with eg. GE Interlogix, Aritech, Visonic, Caddx, Honeywell, ...
- Develop your own X10 Compatible products or X10 Home Automation System
- It plugs into an AC outlet and connects to the OEM product via a telephone jack (not included).
- The Two-Way Interface can also read it's own incorporate error detection and contention resolution into his software or firmware.
- Metal Mounting bracket included
- Two-way TTL/CMOS interface for connecting the Marmitek X10 system with your own applications or with appliances which have a X10 interface entry (alarm systems, thermostats, touch screen controllers, etc.).
- Translates TTL/CMOS signals to Marmitek X10 signals on the existing house wiring and vice versa. Calvinistic divided entry and exit with regard to the existing wiring.
- If you know how to send and read RS232 type serial communication with your computer or from any other electronic device, you can develop and market your own software and/or hardware for use with X10 compatible systems without having to develop your own X10 communications hardware.
- The XM10 is the European equivalent for the US TW523 model.
- Supply voltage: 230 V / 50 Hz
- Operating Temperature Range: - 10° C to + 40°C
- Storage Temperature Range: -20° C to + 70° C
- CE mark
DC Characteristics:
- Serial data input:
- Min. logic "1": 4 V input will sink approx. 2,5 mA
- Max logic "1": 20 V input sink approx. 18 mA
- Max. logic "0": 0.8 V will sink approx. 0,1 mA
(voltages and currents wit repect to terminal 2)
Note: This ouput is an open collector transistor. Therefore, the logic "1" voltage is quoted as a reference for defining the output leackage current. An output pull-up resistor is required to generate a logic level. The pull-up can be returned to any voltage up to 20 V with respect to terminal 2.
AC characteristics:
- HF output to AC powerline: 60 mW average into 5 ohm
- Conforms to Class 116 of EN50065-1: load (5 V pk-pk instant)
- Carrier frequency: 120 kHz
- Max. phase delay between 0 crossing point of AC power line and 0 crossing detect output (either trnasition): 100 µsec
- Max. allowable delay between transitions on 0 crossing detect output and serial data input "0" - "1" transition: 50 µsec
- Max. delay between serial input enveloppe "0" - "1" transition and carrier burst reaching 90%: 50 µsec
- Width of enveloppe: 1 ms +100 µsec -50 µsec
- Isolation voltage: 4 kV ms 50 Hz for 1 min
- Leaflet
- Manual
This module replaces the old TW7223 two-way interface.
Same functionality, but different outside housing.
The XM10 Two-way Interface is available with EURO plug and UK plug. See details on plug types.

The XM10 is the European equivalent for the TW523 USA model. Note that the USA model is NOT suitable for use in Europe, only the XM10 is suitable for use in Europe.
|