PRU256 Programmer/Logger
Commercial Information
The PRU256 Programmer/logger is
able to send and receive both
standard X10 commands as well as
X10 extended commands. Keypad
selections enable selection of transmit
signal levels, single or continuous
signal transmission, user selection of
zero crossing degree shift and display
or log the level of noice or signal on
the power line on the PRU 256 Liquid
Crystal Display (LCD). |
|
- Transmits and Receives both standard as
extended X10 commands
- Displays noise level on the power line
- Displays signal level on the power line
- Can log noise and signal levels over 24h period
- Auto transmit mode for system testing
- Adjustable transmit voltage in 33,3 mV increments
- Time/Date (24h format)
- Selectable 0°, 30°, 60°, 90°, 120°, 150° transmit pulse
- Shows received X10 packets as one frame or two frames: can be used to determine whether signal is repeated
or original
- Can be used as P1 test transmitter when combined with the Marmitek XPTR test receiver (Art.No. 09103)
- Programming tool for Marmitek MicroModules
- Display signal strength on line from other transmitters and two way receivers
- Use to test potential installation sites for possible installation problems
- Pinpoint loads to be filtered by logging power grid noise levels (user defined time periods up to 24 hours)
- Supply voltage : 120 to 277 VAC (+/- 10%)
- Frequency : 50 Hz
- Current draw : 270mA at 240VAC/50Hz
- Receive Parameters : The PRU256 will accept power line carrier transmission signals with minimum strength of 25mV
peak to peak. The carrier frequency of this signal will be 120 kHz ± 4kHz. The pulse width will be 1ms ± 10% and occur no later than 200ms after the zero crossing of the main voltage.
- Transmit Parameters: The PRU256 will output power line carrier transmission signals with a minimum of 6V peak to
peak strength into a power line with a 5 Ohm load attached. The carrier frequency will be 120kHz
± 1kHz. The transmission pulse will be 1ms ± 10% and will start no later than 200ms after the
zero crossing of the mains voltage and when enabled an additional pulse will be transmitted no
later than 200ms after the 30° point of the half wave.
- Transmit Locations: All transmission locations (0°, 30°, 60°, 90°, 120° & 150°) can be individually activated or deactivated
through the SETUP menu.
NOTE: More than four activated transmit locations may deliver unsteady transmit level results.
NOTE: The 0° transmit location must remain enabled if the automatic level adjustment is to remain
active. If the 0° transmission is disabled, the circuit will always adjust to maximum level.
- Transmit level: The level of the powerline carrier transmissions can be adjusted through the setup menu. When
the level is set from 0 to 150 the Automatic level adjustment will be active. This will readjust the
signal level for line loading conditions. The maximum adjustable level is 5V peak to peak (level
settings of 150). Any setting above this will result in a maximum output (>/= 6V peak to peak).
- Display : 16 Character x 2 Row LCD, Bottom viewing angle. Contrast adjustment is possible with
adjustment potentiometer on the right side of case.
Print info
FOR PROFESSIONAL USE ONLY! FOR INSTALLATION CONSULT AN ELECTRICIAN
Neutral required!
|