- Extreme small size (46x46mm and only 16 mm thick)
- Built-in appliance module with 16A rating
- Relay holds last state on power loss
- Low noise relay
- Two-way X10 communication
- Able to change internal ON/OFF state by global commands
like "ALL LIGHTS ON" and "ALL UNITS OFF" to stay in "sync" with modules to which it is configured
- HouseCode, UnitCode and settings can be simply programmed with every X10 compatible controller (e.g. Marmitek 8in1 in combination with TM13 transceiver), except for the CM11 computer interface
- Improved S/N ratio for reliable X10 communication
- Power/Status/Configuration LED
See also : Overview Micromodules (PDF)
- Remote ON/OFF control of electrical loads
- Provides powerline carrier control to existing light switches
- Transforms conventional switches into an X10 transmitter
- Full control of all your X10 modules by conventional switches
- Choose your own brand, design and color for switches and wall sockets
- Place X10 modules out of sight
- Turn every existing wall socket into an X10 controlled wall socket
- Ideal for installation into light fixtures, home appliances & other limited areas
- Install two-way switches without any additional wiring between switches (Marmitek MicroModules transmit their status to other MicroModules through the power line).
- Use a conventional switch on a fixed location to execute Macro's
The AWM2P connects up to 2 momentary or maintained switches by wire leads. External switch 1 (connected to the brown and blue wire) controls the relay and transmits ON/OFF X10 command for the configured address. Switch 2 (connected to the red and blue wire) only transmits an ON/OFF command for the configured address plus one.
New to X10 Home Automation?
 |
Click here to learn more about X10 home automation
and the many possibilities. |
- Power : 230VAC, +10%/-15% , Frequency 50Hz
- Electricity consumption Less than 30 mA capacitive
- Switching power : 3600W 230V with temperature and mounting restrictions.
2300W/230V 500W ind cap
- Signal transmission: > 5Vpp in 5 Ohm at 120 kHz +/- 1kHz
- X10 transmission : 1 pulse burst on 0¢ª and 180¢ª
- Signal sensitivity : 25mVpp ... 6Vpp at 120 kHz +/- 4 kHz
- Signal / interference proportion : 1,35 : 1
- X10 Key codes: All units Off, All Lights On, On, Off, Status Request
- Switch use: normal switches (make/break) or Momentary switches
- Connection range : Up to 2,5 mm²
- 3 phase use : The AWM2P transmits signals for use on 1 phase only. You should use the FKX40 to be able to receive the commands of the AWM2P/SAIX12 on other phases. The AWM2P/SAIX12 does receive commands from standard Marmitek X10 transmitters on different phases.
- Dimensions : 46 x 46 x 16 mm
- Mounting : Sized for mounting of 75mm dia x 50mm deep European round electrical junction box, or other limited areas
- Operating Temperature Range : -10 to +35 degrees C
- Storage Temperature Range : -20 to +70 degrees C
- Product manual
- Specifications may change without notice to improve product performance
- To install the AWM2P, neutral and phase are required at the installation point.
- The AWM2P micromodule can NOT be programmed with the CM11 Computer interface.
- This product is for professional use only. Please consult a qualified electrician if you do not have the technical skills or if you have any doubts about proper installation.
- Usage of the AWM2P MicroModule in a 3 phase installation. The X10 transmitters of the MicroModules transmit the command only once for use in the phase of which they are connected. When you want to receive the commands on your other phases as well, you will need to install a FKX40 phase coupler/repeater
|