- Operate your electric sun blinds, roll down shutters, etc. remotely and/or locally
- Makes your X10 system invisible
- Micromodule with built-in relay with two contacts for connecting a 230V motor.
- Can be operated remotely with an X10 signal or locally,
fully open/closed or on every interim position.
- Invisible installation behind existing switches or wall outlets.
Brand and model of the switch can be chosen freely
so the SW12 can be used in every interior and installation.
- A 2-way momentary switch with zero setting can be connected to this module.
- Quick and easy to install and to program.
This unit allows a motorized blind to be controlled either manually from a momentary switch with two normally open contacts connected to the unit, or remotely by serial X-10 Powerline messages sent from a suitable controller. When controlled serially the blind can be made to go to intermediate settings in addition to fully up or fully down.
Window parameters, such as Window Size and Current Position, together with the unit's address are set into it by the user when the unit is put into Install Mode and these are stored in permanent memory. This data is retained even through a loss of power.
FAQ
What are the differences between SW12 and SWM1P?
| |
SWM1P |
|
SW12 |
Maximum Load
Inductive/capacitive |
500W |
|
700W |
Number of addresses
that can be programmed |
2 |
|
1 |
| X10 communication |
2-way |
|
1-way |
X10 commands
that can be send |
On/Off, Status,
Extended |
|
- |
X10 commands
that can be received |
On/Off, Dim+/Dim-,
Status request, Extended |
|
On/Off, Dim+/Dim-,
Extended |
| Memory |
Preset Function |
|
- |
| Local Lock function |
Yes |
|
No |
| Use in 3-phase installation |
Requires CAT4000 |
|
Requires 3 x FD10
or 1 x CAT4000 |
Status LED
power/ programming |
Yes |
|
No |
- Supply voltage: 230V ±10%, 50 Hz
- Power Consumption: < 1W
- Maximum Load: 700W/230V for motors
- Sensitivity to power line signals: 50mV p-pk @ 120 KHz. For signals > 50mV AGC is applied
- X10 Key codes On, Off, DIM+, DIM-, extended
- Terminals: Screw terminals for L, N, UP (relay), DN (relay)
- Wires : for UP key (blue) and DOWN (orange)
- Switch: momentary switch with two normally open contacts
- in wall junction box : Minimal 40mm, preferred: 50mm
- Ambient temperature:: 0-40° C
- Dimensions: 46x46x17mm
- Download foder - Download manual
|