- Repeats all Xanura & Marmitek X10 commands
- To be installed in a junction box
- Can be used in single phase installations with low Xanura / Marmitek X10
signal levels where equipment filters are not satisfactory.
- Amplifies Xanura / X10 signals to their maximum value.
- The signal amplifier amplifies all letter codes as standard.
- Can be set up to amplify a single or several letter codes.
The LED is on all the time when in operating mode. The LED flashes when Xanura / X10 signals are received and amplified.
The SVX10 only works if the original signal level in the fuse compartment is at least 100 mV. Each letter code for a building can only be amplified by one signal amplifier. The signal amplifier must not be used in combination with an FKX phase connector.
- The signal amplifier must be mounted in the meter cupboard, a junction box or welding box. The signal amplifier must be protected by a 16 A automatic fuse or fuse link.
- Each letter code for a building can only be amplified by one signal amplifier.
- Connect the phase and neutral wire to the terminals on the signal amplifier, see Figure 1 of the manual
- Program the module if it has not already been programmed, or has been programmed incorrectly.
|